Biến tần LSLV0055H100

Biến tần LSLV0055H100

0 Lượt mua | 2303 Lượt xem

9,220,000 VNĐ

Mã sản phẩm: LSLV0055H100

Nhãn hiệu: LS

LSLV-H100 drives are intelligent drives equipped with various protective and operation functions for continuously stable operation in response to external environmental...

Tùy chọn:

Số lượng:

LSLV-H100 drives are intelligent drives equipped with various protective and operation functions for continuously stable
operation in response to external environmental changes.


Soft Fill Operation
Prevents pump damages caused by dramatic pressure
changes during intial operation or pumps or inside
pumps.

Start Ramp & End Ramp
Prevents pump damage by changing ramp using
acceleration / deceleration time setting upon initial
pump operation and stop

 

Dec Valve Ramp
Prevents pump and pipe damages caused by sudden
pressure changes when pumps are stopped or a pump
valve is closed, deceleration time can be set.
 
Multi Motor Control
MMC is used when a single drive is used to control
multiple motors in pump systems.
It can control 1 main motor and 5 auxiliary motors.
Pump Clean
Upon pump operation, the efficiency of pumps may
decline when foreign substances are stuck in an
impeller. Pump Clean removes the foreign substances
to extend the pump life and reduce any loss

 
Aux Motor PID Compensation
Pipe flow increases and conduit pressure decreases
as the number of auxiliary motors increases. To
compensate this, 'Aux Motor PID Compensation' is
used to compensate pressure loss suitable for the
given motor when operating auxliary motors.

Load Tuning
Establishes load (current & power) curves based on
drive frequency so as to make load characteristics
curve required for 'Under Load' and 'Pump Clean.'


 

Fire Mode
When an emergency such as fire occurs at suction/
exhaust fans, but hardware did not fail nor had a
critical defect, the drive is continuously operated to
protect other systems under the set frequency and
direction.

Energy-saving Display (Payback Counter)
Commercial energy consumption is compared to the
amount of enery used by the drive to calculate the
amount of energy saved.

Power-on Resume
When the drive restarts after it was stopped due to power
interruption upon communication control, 'Power-on
Resume' is used to follow the previous control command.

Sleep, Sleep Boost, Wake-up
It is used to put the drive on standby and restarts it
using amount of enery used by the drive to calculate
the amount of energy saved.

Auto Torque Boost
The drive outputs voltage for the drive by controlling
the level of boost to fit the load by itself.

Lubrication Control
When a control command is made in the Flow/Oiling
Systems, lubrication signals are output for a certain
period before the motors are started. Drive control is
immediately started form the signal output point until
the signals are turned off after the set time

Damper Control 
When a Damper exists in the system configuration,
the drive will command the Damper to open/close or
receive feedback signals for protection. 


 

Detection of Pipe Broken
Upon PID operation, pipe damages or leakage is
detected to display a warning or a trip.

 

Level Detection
When the drive is operated under frequency that is
beyond the set frequency and source (voltage, current,
and etc.) values to be detected are above or below the
user set values, it generates a trip or activates a
relay for protective operation

Pre-Heat
Pre-heats motors by outputting direct current when
the motors are at fixed time state in order to prevent
condensation of the motors

Under Load Protection
When running pumps including No Flow and Dry Pumps
under the set frequency. the drive issues warning
function and when trip is generates, Free-Run,
deceleration, or stop can be selected via parameters.

Macro Setting
If a particular application is selected, frequently used
parameters and set values are changed and registered
in a macro group

KEB, Kinetic Energy Buffering
Upon loss or momentary interruption of input power,
if KEB is set, the drive maintains DC Link Voltage using
regeneration energy of the motor is used during the
interruption period.

Vui lòng liên hệ BITEK để nhận báo giá tốt nhất cho sản phẩm Biến tần LSLV0055H100

Hotline tư vấn hỗ trợ: 0938992337